Real-time volume intracardiac echo imaging for Tricuspid clip: Supported by ACUSON AcuNav Volume ICE catheter

Average (ratings)
No ratings
Your rating

Overview

Clipping the tricuspid valve is challenging and imaging with transesophageal echocardiography (TEE) can be limited. In this webinar, experts in structural heart procedures will showcase how the wide angle of the ACUSON AcuNav™ Volume ICE catheter can make a difference in guiding you through these procedures. Showing footage from a live-case at Gaia/Espinho Hospital Center, Portugal, the presenters draw on their clinical experience using this device to provide an in-depth presentation and discussion on how the ACUSON AcuNav™ Volume ICE catheter is designed to meet the current needs of the structural heart market. With its increased field of view (90°x50°), it provides visualization of valvular structures for valve repair and replacement, along with the established capabilities and benefits of intracardiac echocardiography. Towards the end of the webinar, the audience will have an opportunity to ask the presenters about the ACUSON AcuNav™ Volume ICE catheter and the presented procedures.

ACUSON AcuNav™ Volume ICE catheter is 510(k) approved. Verification of mutual compatibility of medical devices combined in a system according to Article 12 of the Medical Devices Directive (MDD) 93/42/EEC is pending. Thus, the product is not commercially available in the European Union.

Faculty:


José Ribeiro

José Ribeiro


Pedro Braga

Pedro Braga

This webinar is supported by

Key Learning Objectives

  • How and when the Volume ICE technology can be used as an alternative to the 3D TEE.
  • The advantages of Volume ICE versus 3D TEE imaging of anatomical structures in the right heart due to proximity.
  • How the 90°x50° real-time Volume ICE catheter can be used in structural heart imaging procedures.
  • Display options for Volume ICE viewing of the tricuspid valve to facilitate real-time imaging guidance.
  • The potential to use conscious sedation for this type of procedure.

Target Audience

  • Interventional cardiologists treating structural heart diseases
  • Echocardiographers

Faculty Biographies


José Ribeiro

José Ribeiro

Dr Pedro Braga is Head of the Cardiology Department at Gaia/Espinho Hospital Center, Portugal. Dr Braga graduated from the Faculty of Medicine of the University of Porto in 1985 and completed his specialist training in Cardiology in 1994. He has also worked as an interventional cardiologist at the Hospital of Luz Arrábida and Hospital of Porto. Between 2011 and 2013, Dr Braga was a board member of the Portuguese Society of Cardiology as well as part of the board of directors of the Portuguese Association of Interventional Cardiology.

View full profile

Pedro Braga

Pedro Braga

Dr Pedro Braga is Head of the Cardiology Department at Gaia/Espinho Hospital Center, Portugal. Dr Braga graduated from the Faculty of Medicine of the University of Porto in 1985 and completed his specialist training in Cardiology in 1994. He has also worked as an interventional cardiologist at the Hospital of Luz Arrábida and Hospital of Porto. Between 2011 and 2013, Dr Braga was a board member of the Portuguese Society of Cardiology as well as part of the board of directors of the Portuguese Association of Interventional Cardiology.